05/98
3.1M54EA1 059821 Order No. DIN size 7.02143.31.00
US size 7.02143.71.00
0.73.00
CONTENTS
Installation in the pipeline Pages 4-5 and 7-8
Grounding Pages 8-9
Installation
instructions
VARIFLUX
IFS 6000 F
IFM 6010 K
IFM 6020 K
IFM 6080 K
IFM 1010 K
IFM 1080 K
Electromagnetic
flowmeters
• Primary heads
• Compact flowmeters
IFM 6010 K IFM 6080 K
IFS 6000 F
Przeglądanie stron 0
1 2 3 4 5 6 ... 14 15

Podsumowanie treści

Strona 1 - Electromagnetic

05/983.1M54EA1 059821 Order No. DIN size 7.02143.31.00US size 7.02143.71.000.73.00CONTENTSInstallation in the pipeline Pages 4-5 and 7-8Grounding Page

Strona 2

10Switch off power source before commencing work!1) Note down terminal assignment before dismantling the “old“ primary head.2) Install the new primary

Strona 3 - * not to ISO 2037

1110 Technical dataSize/type DN 2.5 - 80 and 1/10” - 3”Available connections see page 3Electrical conductivity ≥ 5 µS/cm (≥ 20 µS/cm for deminerali

Strona 4

1211 Dimensions and weightsPLEASE NOTEThe total dimension for the height is obtained from dimension b (see table) plus the heightof the terminal bo

Strona 5 - > 16 ft

13160 (6.30,,)136 (5.35,,)098 (3.86,,)208 (8.19,,) Ex: 238 (9.37,,)140 (5.51,,)078 (3.07,,)Lm071 (2.80,,)105 (4.13,,)165 (6.50,,) ebdDimensions with

Strona 6

14Dairy screw connection to DIN 11 851Connection meter size dia. D LAaDN 10 1)038 (1.50)47.0 (1.85)214 ( 8.43)DN 15DN 25 063 (2.48) 230 (9.06)D

Strona 7

15If you need to return flowmeters for testingor repair to KrohneSPECIMEN certificateYour electromagnetic flowmeter• has been carefully manufactured

Strona 8

2ContentsSystem description 2Product liability and warranty 2Standards and approvals 2Items included with supply 31 Important information for instal

Strona 9

3Items included with supplyIFS 6000 F primary head• primary headin the size as ordered• certificate of calibration data• installation instructionsIFM

Strona 10

41 Important information for installation: PLEASE NOTE• Location and position as required,but electrode axis X – • – • – • – Xmust be approximately ho

Strona 11

5• Strong electromagnetic fields, avoid in vicinity of flowmeter.• Straight inlet run minimum of 5 ××DN and outlet run minimum of 2 ××DN,(DN = meter s

Strona 12

63 Instrument nameplateTeflon®is a registered trademark of Du PontInstrument nameplate for compact flowmeterssee installation and operating instru

Strona 13 - DN 25 - 80 / 1” - 3”

75 Installation in the pipelineLmaxLmin• Installation material, see page 3.• Pipe and operating pressures,see Section 6 “Limits”.• Flange spacing= dim

Strona 14 - Clamp joint ISO 2852

86 Limits7. Grounding• Warning: All flowmeters must be properly grounded to avoid personnel shock hazard.• The ground conductor should not transm

Strona 15 - SPECIMEN certificate

9Supply power > 50 V AC• Grounding is via the PE protective ground conductor incorporated in the power supplycable, see also Section “Connection to